{"product_id":"honeywell-tc809e-input-output-module","title":"Honeywell TC809E Input\/Output Module","description":"\u003ch3 data-section-id=\"1cipt4w\" data-start=\"174\" data-end=\"236\"\u003eHoneywell TC809E Input\/Output Module\u003c\/h3\u003e\n\u003cp data-start=\"238\" data-end=\"537\"\u003eThe \u003cstrong data-start=\"242\" data-end=\"269\"\u003eHoneywell TC809E series\u003c\/strong\u003e are intelligent addressable \u003cstrong data-start=\"298\" data-end=\"322\"\u003einput\/output modules\u003c\/strong\u003e designed for fire alarm and building management systems. They are used to monitor external devices (such as switches or detectors) and control auxiliary equipment like fire dampers, shutters, and signaling devices.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"709\"\u003eThe TC809E modules are part of Honeywell’s modular interface family and are widely used in \u003cstrong data-start=\"630\" data-end=\"668\"\u003eaddressable fire detection systems\u003c\/strong\u003e for commercial and industrial buildings.\u003c\/p\u003e\n\u003chr data-start=\"711\" data-end=\"714\"\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"716\" data-end=\"732\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"734\" data-end=\"1301\"\u003e\n\u003cli data-section-id=\"51qhra\" data-start=\"734\" data-end=\"796\"\u003ePart of Honeywell \u003cstrong data-start=\"754\" data-end=\"794\"\u003eTC800 \/ M200 series interface family\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9la9ku\" data-start=\"797\" data-end=\"862\"\u003eSupports \u003cstrong data-start=\"808\" data-end=\"860\"\u003einput monitoring and\/or output control functions\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ptfiqo\" data-start=\"863\" data-end=\"1013\"\u003eAvailable versions:\n\u003cul data-start=\"887\" data-end=\"1013\"\u003e\n\u003cli data-section-id=\"18wfag8\" data-start=\"887\" data-end=\"923\"\u003eTC809E1043 – Single input module\u003c\/li\u003e\n\u003cli data-section-id=\"1dyfkek\" data-start=\"926\" data-end=\"960\"\u003eTC809E1050 – Dual input module\u003c\/li\u003e\n\u003cli data-section-id=\"1m2qb2h\" data-start=\"963\" data-end=\"1013\"\u003eTC809E1068 – Dual input + single output module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2gza2z\" data-start=\"1014\" data-end=\"1055\"\u003eBuilt-in \u003cstrong data-start=\"1025\" data-end=\"1053\"\u003eshort-circuit protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kltl8v\" data-start=\"1056\" data-end=\"1097\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1095\"\u003eAddressable device (loop powered)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"6gw54c\" data-start=\"1098\" data-end=\"1154\"\u003eLED status indicators (multi-color) for each channel\u003c\/li\u003e\n\u003cli data-section-id=\"1ykafor\" data-start=\"1155\" data-end=\"1200\"\u003eConfigurable via fire alarm control panel\u003c\/li\u003e\n\u003cli data-section-id=\"1h6evff\" data-start=\"1201\" data-end=\"1256\"\u003eFlexible mounting: DIN rail, wall box, or enclosure\u003c\/li\u003e\n\u003cli data-section-id=\"960b1g\" data-start=\"1257\" data-end=\"1301\"\u003eSuitable for EN54-compliant fire systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1303\" data-end=\"1306\"\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1308\" data-end=\"1336\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1338\" data-end=\"1519\"\u003e\n\u003cli data-section-id=\"1x3c5s5\" data-start=\"1338\" data-end=\"1366\"\u003e\n\u003cstrong data-start=\"1340\" data-end=\"1357\"\u003eModel Series:\u003c\/strong\u003e TC809E\u003c\/li\u003e\n\u003cli data-section-id=\"14f9qfe\" data-start=\"1367\" data-end=\"1412\"\u003e\n\u003cstrong data-start=\"1369\" data-end=\"1378\"\u003eType:\u003c\/strong\u003e Addressable input\/output module\u003c\/li\u003e\n\u003cli data-section-id=\"1m97mba\" data-start=\"1413\" data-end=\"1519\"\u003e\n\u003cstrong data-start=\"1415\" data-end=\"1433\"\u003eCommunication:\u003c\/strong\u003e Fire alarm loop (addressable system protocol) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1521\" data-end=\"1536\"\u003e\u003cstrong data-start=\"1521\" data-end=\"1536\"\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1537\" data-end=\"1797\"\u003e\n\u003cli data-section-id=\"cmg4pp\" data-start=\"1537\" data-end=\"1620\"\u003eOperating voltage: approx. \u003cstrong data-start=\"1566\" data-end=\"1580\"\u003e15–32 V DC\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"htya3r\" data-start=\"1621\" data-end=\"1699\"\u003eLow standby current (microamp range) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lfwvu1\" data-start=\"1700\" data-end=\"1797\"\u003eRelay output rating (TC809E1068): \u003cstrong data-start=\"1736\" data-end=\"1757\"\u003eup to 30 VDC \/ 2A\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1799\" data-end=\"1817\"\u003e\u003cstrong data-start=\"1799\" data-end=\"1817\"\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1818\" data-end=\"1977\"\u003e\n\u003cli data-section-id=\"wuu4wo\" data-start=\"1818\" data-end=\"1901\"\u003eOperating temperature: \u003cstrong data-start=\"1843\" data-end=\"1861\"\u003e−20°C to +60°C\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jqubc1\" data-start=\"1902\" data-end=\"1977\"\u003eHumidity: 5%–95% (non-condensing) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1979\" data-end=\"1982\"\u003e\n\u003ch3 data-section-id=\"6lh1wf\" data-start=\"1984\" data-end=\"2011\"\u003eFunctional Capabilities\u003c\/h3\u003e\n\u003cul data-start=\"2013\" data-end=\"2382\"\u003e\n\u003cli data-section-id=\"uadbod\" data-start=\"2013\" data-end=\"2101\"\u003eMonitoring of \u003cstrong data-start=\"2029\" data-end=\"2062\"\u003enormally open contact devices\u003c\/strong\u003e (e.g., fire alarm switches, sensors)\u003c\/li\u003e\n\u003cli data-section-id=\"1e7dwh0\" data-start=\"2102\" data-end=\"2174\"\u003eControl of external equipment (only in I\/O versions like TC809E1068)\u003c\/li\u003e\n\u003cli data-section-id=\"1e883wa\" data-start=\"2175\" data-end=\"2269\"\u003eFault detection (open circuit, short circuit supervision depending on panel configuration)\u003c\/li\u003e\n\u003cli data-section-id=\"1y074tt\" data-start=\"2270\" data-end=\"2323\"\u003eIndividual LED indication for input\/output status\u003c\/li\u003e\n\u003cli data-section-id=\"y5xqz8\" data-start=\"2324\" data-end=\"2382\"\u003eAutomatic addressing through fire control panel system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2384\" data-end=\"2387\"\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2389\" data-end=\"2405\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2407\" data-end=\"2596\"\u003e\n\u003cli data-section-id=\"1tcgjvp\" data-start=\"2407\" data-end=\"2452\"\u003eFire alarm systems (addressable networks)\u003c\/li\u003e\n\u003cli data-section-id=\"1pblahy\" data-start=\"2453\" data-end=\"2478\"\u003eSmoke control systems\u003c\/li\u003e\n\u003cli data-section-id=\"tjty8p\" data-start=\"2479\" data-end=\"2515\"\u003eFire dampers and shutter control\u003c\/li\u003e\n\u003cli data-section-id=\"1hfxnen\" data-start=\"2516\" data-end=\"2551\"\u003eBuilding automation integration\u003c\/li\u003e\n\u003cli data-section-id=\"13072b6\" data-start=\"2552\" data-end=\"2596\"\u003eIndustrial and commercial safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2598\" data-end=\"2601\"\u003e\n\u003ch3 data-section-id=\"vx82wf\" data-start=\"2603\" data-end=\"2628\"\u003eAdvantages for Buyers\u003c\/h3\u003e\n\u003cul data-start=\"2630\" data-end=\"2905\"\u003e\n\u003cli data-section-id=\"46a30o\" data-start=\"2630\" data-end=\"2682\"\u003eHigh reliability in critical fire safety systems\u003c\/li\u003e\n\u003cli data-section-id=\"120wx5y\" data-start=\"2683\" data-end=\"2745\"\u003eFlexible input\/output configurations in one product family\u003c\/li\u003e\n\u003cli data-section-id=\"kfukg4\" data-start=\"2746\" data-end=\"2800\"\u003eEasy installation (DIN rail or enclosure mounting)\u003c\/li\u003e\n\u003cli data-section-id=\"xxol3e\" data-start=\"2801\" data-end=\"2854\"\u003eCompatible with Honeywell addressable fire panels\u003c\/li\u003e\n\u003cli data-section-id=\"wqzs18\" data-start=\"2855\" data-end=\"2905\"\u003eWidely used in professional EN54 installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Digital Shop","offers":[{"title":"Default Title","offer_id":53675983044974,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/6696\/1518\/files\/IMG_20230525_162439.jpg?v=1777317309","url":"https:\/\/dykenshop.com\/products\/honeywell-tc809e-input-output-module","provider":"Digital Shop","version":"1.0","type":"link"}