{"product_id":"tyco-flamevision-fv412f","title":"Tyco FLAMEVision FV412F – Triple IR Flame Detector","description":"\u003ch3 data-section-id=\"10tslo8\" data-start=\"0\" data-end=\"76\"\u003eTyco FLAMEVision FV412F – Triple IR Flame Detector\u003c\/h3\u003e\n\u003cp data-start=\"78\" data-end=\"436\"\u003eThe \u003cstrong data-start=\"82\" data-end=\"123\"\u003eTyco FLAMEVision FV412F (516.300.412)\u003c\/strong\u003e is a professional \u003cstrong data-start=\"142\" data-end=\"171\"\u003eindustrial flame detector\u003c\/strong\u003e designed for early detection of hydrocarbon fires in high-risk environments. It uses advanced \u003cstrong data-start=\"266\" data-end=\"314\"\u003etriple infrared (IR3) solar-blind technology\u003c\/strong\u003e combined with intelligent flame recognition algorithms to provide fast, reliable detection while minimizing false alarms.\u003c\/p\u003e\n\u003cp data-start=\"438\" data-end=\"621\"\u003eThis model is part of the \u003cstrong data-start=\"464\" data-end=\"492\"\u003eFV400 FLAMEVision series\u003c\/strong\u003e, widely used in oil \u0026amp; gas, petrochemical, industrial, and hazardous-area installations where high safety standards are required.\u003c\/p\u003e\n\u003chr data-start=\"623\" data-end=\"626\"\u003e\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"628\" data-end=\"644\"\u003eKey Features\u003c\/h3\u003e\n\u003cul data-start=\"646\" data-end=\"1267\"\u003e\n\u003cli data-section-id=\"16rzb46\" data-start=\"646\" data-end=\"696\"\u003e\u003cstrong data-start=\"648\" data-end=\"694\"\u003eTriple IR (IR3) flame detection technology\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"19x6zkr\" data-start=\"697\" data-end=\"766\"\u003eHigh resistance to false alarms (sunlight, welding, hot surfaces)\u003c\/li\u003e\n\u003cli data-section-id=\"1cvrlxa\" data-start=\"767\" data-end=\"841\"\u003eDetection of hydrocarbon fires (gasoline, oil, alcohol, aviation fuel)\u003c\/li\u003e\n\u003cli data-section-id=\"f5vbfk\" data-start=\"842\" data-end=\"904\"\u003eCan detect flames through \u003cstrong data-start=\"870\" data-end=\"902\"\u003esmoke and vapor environments\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h54ofl\" data-start=\"905\" data-end=\"1019\"\u003eDetection range up to \u003cstrong data-start=\"929\" data-end=\"979\"\u003e~65 meters (for standard test fire conditions)\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pmh29t\" data-start=\"1020\" data-end=\"1087\"\u003eOptional \u003cstrong data-start=\"1031\" data-end=\"1085\"\u003eintegrated PAL CCTV camera for visual verification\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w5vhw5\" data-start=\"1088\" data-end=\"1139\"\u003eBuilt-in self-check and optical path monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"ypmc93\" data-start=\"1140\" data-end=\"1217\"\u003eMultiple industrial communication interfaces (depending on configuration)\u003c\/li\u003e\n\u003cli data-section-id=\"1s2d340\" data-start=\"1218\" data-end=\"1267\"\u003eDesigned for harsh and hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1269\" data-end=\"1272\"\u003e\n\u003ch3 data-section-id=\"nucr17\" data-start=\"1274\" data-end=\"1302\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul data-start=\"1304\" data-end=\"1497\"\u003e\n\u003cli data-section-id=\"10epfj0\" data-start=\"1304\" data-end=\"1325\"\u003e\n\u003cstrong data-start=\"1306\" data-end=\"1316\"\u003eModel:\u003c\/strong\u003e FV412F\u003c\/li\u003e\n\u003cli data-section-id=\"ynl9sg\" data-start=\"1326\" data-end=\"1358\"\u003e\n\u003cstrong data-start=\"1328\" data-end=\"1344\"\u003ePart Number:\u003c\/strong\u003e 516.300.412\u003c\/li\u003e\n\u003cli data-section-id=\"gjnid3\" data-start=\"1359\" data-end=\"1420\"\u003e\n\u003cstrong data-start=\"1361\" data-end=\"1380\"\u003eDetection Type:\u003c\/strong\u003e Triple Infrared (IR3) flame detection\u003c\/li\u003e\n\u003cli data-section-id=\"46rjdf\" data-start=\"1421\" data-end=\"1497\"\u003e\n\u003cstrong data-start=\"1423\" data-end=\"1438\"\u003eTechnology:\u003c\/strong\u003e Solar-blind IR sensors with flame recognition algorithms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1499\" data-end=\"1515\"\u003e\u003cstrong data-start=\"1499\" data-end=\"1515\"\u003ePerformance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1516\" data-end=\"1687\"\u003e\n\u003cli data-section-id=\"5xrvld\" data-start=\"1516\" data-end=\"1574\"\u003eHigh-speed flame response (early detection capability)\u003c\/li\u003e\n\u003cli data-section-id=\"1ws77sw\" data-start=\"1575\" data-end=\"1621\"\u003eStable detection across full field of view\u003c\/li\u003e\n\u003cli data-section-id=\"l8g1zc\" data-start=\"1622\" data-end=\"1687\"\u003eReliable performance in smoke and contaminated air conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1689\" data-end=\"1714\"\u003e\u003cstrong data-start=\"1689\" data-end=\"1714\"\u003eOutputs \/ Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1715\" data-end=\"1883\"\u003e\n\u003cli data-section-id=\"5ejpxv\" data-start=\"1715\" data-end=\"1745\"\u003eFire \u0026amp; fault relay outputs\u003c\/li\u003e\n\u003cli data-section-id=\"raicth\" data-start=\"1746\" data-end=\"1790\"\u003e4–20 mA signal output (system dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"tsvl4o\" data-start=\"1791\" data-end=\"1838\"\u003eOptional video output via integrated camera\u003c\/li\u003e\n\u003cli data-section-id=\"dagnyw\" data-start=\"1839\" data-end=\"1883\"\u003eConfiguration and maintenance interfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1885\" data-end=\"1888\"\u003e\n\u003ch3 data-section-id=\"6qg9yl\" data-start=\"1890\" data-end=\"1918\"\u003ePhysical \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul data-start=\"1920\" data-end=\"2164\"\u003e\n\u003cli data-section-id=\"14l0hb4\" data-start=\"1920\" data-end=\"1976\"\u003eRugged industrial housing for outdoor\/industrial use\u003c\/li\u003e\n\u003cli data-section-id=\"1t13bq9\" data-start=\"1977\" data-end=\"2065\"\u003eDesigned for hazardous and explosion-risk zones (depending on certification variant)\u003c\/li\u003e\n\u003cli data-section-id=\"niwmu6\" data-start=\"2066\" data-end=\"2116\"\u003eResistant to harsh weather, dust, and humidity\u003c\/li\u003e\n\u003cli data-section-id=\"1p5473n\" data-start=\"2117\" data-end=\"2164\"\u003eSuitable for long-term continuous operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2166\" data-end=\"2169\"\u003e\n\u003ch3 data-section-id=\"wggvqn\" data-start=\"2171\" data-end=\"2187\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"2189\" data-end=\"2387\"\u003e\n\u003cli data-section-id=\"14obaeq\" data-start=\"2189\" data-end=\"2213\"\u003eOil \u0026amp; gas facilities\u003c\/li\u003e\n\u003cli data-section-id=\"1qs4a2s\" data-start=\"2214\" data-end=\"2238\"\u003ePetrochemical plants\u003c\/li\u003e\n\u003cli data-section-id=\"115b1qs\" data-start=\"2239\" data-end=\"2270\"\u003eIndustrial production sites\u003c\/li\u003e\n\u003cli data-section-id=\"1nm299r\" data-start=\"2271\" data-end=\"2293\"\u003eFuel storage areas\u003c\/li\u003e\n\u003cli data-section-id=\"1ke4ysc\" data-start=\"2294\" data-end=\"2331\"\u003eOffshore and marine installations\u003c\/li\u003e\n\u003cli data-section-id=\"1nlueyh\" data-start=\"2332\" data-end=\"2387\"\u003eHigh-risk fire zones requiring fast flame detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2389\" data-end=\"2392\"\u003e\n\u003ch3 data-section-id=\"vx82wf\" data-start=\"2394\" data-end=\"2419\"\u003eAdvantages for Buyers\u003c\/h3\u003e\n\u003cul data-start=\"2421\" data-end=\"2678\"\u003e\n\u003cli data-section-id=\"pqhf5w\" data-start=\"2421\" data-end=\"2464\"\u003eExtremely fast flame detection response\u003c\/li\u003e\n\u003cli data-section-id=\"1xvxssu\" data-start=\"2465\" data-end=\"2503\"\u003eVery high immunity to false alarms\u003c\/li\u003e\n\u003cli data-section-id=\"15yysxq\" data-start=\"2504\" data-end=\"2557\"\u003eWorks in smoke-heavy or contaminated environments\u003c\/li\u003e\n\u003cli data-section-id=\"3116e6\" data-start=\"2558\" data-end=\"2617\"\u003eOptional CCTV verification reduces operator uncertainty\u003c\/li\u003e\n\u003cli data-section-id=\"xk6rul\" data-start=\"2618\" data-end=\"2678\"\u003eIndustrial-grade reliability for critical safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2680\" data-end=\"2683\"\u003e\n\u003ch3 data-section-id=\"12ad3h7\" data-start=\"2685\" data-end=\"2723\"\u003eShort Sales Summary (for listings)\u003c\/h3\u003e\n\u003cp data-start=\"2725\" data-end=\"3017\"\u003e\u003cstrong data-start=\"2725\" data-end=\"2767\"\u003eTyco FLAMEVision FV412F Flame Detector\u003c\/strong\u003e – advanced triple IR industrial flame detector with up to 65m detection range, high false alarm immunity, and optional integrated camera for visual fire verification. Ideal for oil \u0026amp; gas, industrial safety, and hazardous area fire detection systems.\u003c\/p\u003e","brand":"Digital Shop","offers":[{"title":"Default Title","offer_id":53675727225198,"sku":null,"price":5800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0993\/6696\/1518\/files\/IMG_20230525_153318.jpg?v=1777306821","url":"https:\/\/dykenshop.com\/products\/tyco-flamevision-fv412f","provider":"Digital Shop","version":"1.0","type":"link"}